Postcode intelligence
B31 · Northfield · Longbridge
Every domestic energy certificate lodged in B31, as held on the national register. 18,695 properties.
68
Median SAP score
Band D
9,591
Below band C
51.3% of stock
953
Cannot reach C at all
5.1%
1,039
Expiring in 12 months
5,103 already lapsed
Median property in B31 scores 68. The legal minimum for a private tenancy from October 2030 is 69.
What the stock looks like
- Dominant property type
- House
- Dominant built form
- Semi-Detached
- Dominant age band
- England and Wales: 1930-1949
- Median floor area
- 75 m²
- Privately or socially rented
- 0 (0%)
- Median potential score
- 83
Where B31 loses its points
Mean element rating across every certificate in the district, on the register’s one-to-five scale. Lower is worse.
- walls2.9
- windows3.4
- roof3.5
Typical gains from common measures
Estimated from certificates lodged across B, DY, WS and WV in the last five years. Ranges are 90% confidence intervals — treat these as typical, not as a prediction for any one property.
| Measure | Typical gain | Indicative cost |
|---|---|---|
| High heat retention storage heaters and dual immersion cylinder | 14.3–14.7 pts | £1,200–£1,800 |
| High heat retention storage heaters | 8.0–8.3 pts | £1,200–£1,800 |
| Solar water heating | 5.8–5.9 pts | £4,000–£6,000 |
| 50 mm internal or external wall insulation | 5.7–5.8 pts | £4,000–£14,000 |
| Solar photovoltaic panels, 2.5 kWp | 5.7–5.8 pts | £3,500–£5,500 |
50 months to the deadline
9,591 properties in B31 are below band C. From 1 October 2030 none of them can be let until they reach it.
Book an assessmentCheck a specific addressSource: Energy Performance of Buildings Register, MHCLG. Figures cover lodged certificates only and exclude properties never assessed. An EPC is valid for ten years. How these figures are calculated.