RiverstoneEco SolutionsDomestic energy assessmentGuidesPostcode dataPricesBook an assessment

Postcode intelligence

WS8 · Brownhills

Every domestic energy certificate lodged in WS8, as held on the national register. 4,766 properties.

68

Median SAP score

Band D

2,488

Below band C

52.2% of stock

143

Cannot reach C at all

3%

323

Expiring in 12 months

1,734 already lapsed

G
F
E
D
C
B
A

Median property in WS8 scores 68. The legal minimum for a private tenancy from October 2030 is 69.

What the stock looks like

Dominant property type
House
Dominant built form
Semi-Detached
Dominant age band
England and Wales: 1950-1966
Median floor area
76 m²
Privately or socially rented
0 (0%)
Median potential score
83

Where WS8 loses its points

Mean element rating across every certificate in the district, on the register’s one-to-five scale. Lower is worse.

Typical gains from common measures

Estimated from certificates lodged across B, DY, WS and WV in the last five years. Ranges are 90% confidence intervals — treat these as typical, not as a prediction for any one property.

MeasureTypical gainIndicative cost
High heat retention storage heaters and dual immersion cylinder14.3–14.7 pts£1,200–£1,800
High heat retention storage heaters8.0–8.3 pts£1,200–£1,800
Solar water heating5.8–5.9 pts£4,000–£6,000
50 mm internal or external wall insulation5.7–5.8 pts£4,000–£14,000
Solar photovoltaic panels, 2.5 kWp5.7–5.8 pts£3,500–£5,500

50 months to the deadline

2,488 properties in WS8 are below band C. From 1 October 2030 none of them can be let until they reach it.

Book an assessmentCheck a specific address

Source: Energy Performance of Buildings Register, MHCLG. Figures cover lodged certificates only and exclude properties never assessed. An EPC is valid for ten years. How these figures are calculated.